Jump to content
Main menu
Main menu
move to sidebar
hide
Navigation
Main page
Recent changes
Random page
Help about MediaWiki
Luter 345 Experiments
Search
Search
Appearance
Create account
Log in
Personal tools
Create account
Log in
Pages for logged out editors
learn more
Contributions
Talk
Editing
Coda group
(section)
Page
Discussion
English
Read
Edit
Edit source
View history
Tools
Tools
move to sidebar
hide
Actions
Read
Edit
Edit source
View history
General
What links here
Related changes
Special pages
Page information
Get shortened URL
Appearance
move to sidebar
hide
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
== Tube Characterization Scans (Freeman) == === Introduction === In order to find the proper threshold, our first run, we adjusted the threshold on the "discriminator card". The next 4 sets of scans we adjusted the voltage and then let coda run for a fixed amount of time (600 s). This gave us some event count. By plotting the log(Rate) vs. Voltage we are able to characterize each tube and find at which voltages we get all noise and for which voltages we get peak signal. === Scans === ==== Run Plans and Discussion ==== ===== Rate vs. Threshold Measurements ===== Our original plan was to scan through thresholds 100mV - 2000mV at 100mV steps and used a voltage of 1550 V . We began by adjusting the threshold, then let coda run for 1000 events. We recorded the start and stop time of coda. From this we are able to extract a time delta, and then calculate a rate. We found very quickly that as we increased the threshold from 100mV, 200mV, and then 300mV that if we continued to use 1000 events it would take many hours to complete the upper thresholds. We decided to lower the amount of collected rates to 250 events. Equally as we raised the threshold to higher values we found that cutting off the max threshold was a good idea. We plotted and fit our data after we found the first few points. This allowed us to see an exponentially decreasing plot. With a threshold of 500mV we have, nearly, a zero rate. We decided to not go to any higher thresholds, but to fill in some of the gaps and took more data points from 150mV - 450 mV By plotting the log(Rate) vs. Threshold we were able to see a plot that has a linearly decreasing slope, roughly picking where the line crosses the y=0 we chose a threshold of about 250mV. ===== Rate vs. Voltage Measurements ===== Original plan was fix the number of rates such as was found in the threshold scans, this proved to be cumbersome. We eventually change to a fixed number of time 600s and then got then allowed coda to collect events. === Results === ==== Root Macro ==== ==== Graphs ====
Summary:
Please note that all contributions to Luter 345 Experiments may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
Luter 345 Experiments:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)